Descirption:
and
Features:
New upgrades to simplify,to meet customer needs.
Increase the supply anti-reversefunction.
The use of opto isolated input and output,enhanced anti-jamming capabilit
consumption.
Set parameter after power for ever memories.
terminal can be maintained for a longtime.
to stability,industrial grade board,class PLC.
Product
parameters:
Size:64.2mm*34.8mm*18.5mm.
Specifications:AC 220V 10A or for 30V 10A.
Quiescent Current:20mA,Operating Current:50mA.
Working :10~16V (if other ranges can be customized).
:4V~20V (if other ranges can be customized).
life:about100,000times,Working temperature:-40~85'C.
Quantity: 1Pc
 
Working mode selection:
After power on,long press seconds later into the select function mode,P1-1~P1-4forchoose.
P1-1 operating modes:a to , for time is up,the disconnect users,You can set for time for T, K2 the hundreddigital tube starts flashing,then press K3, the hundred digital change; K2 ten digital tube starts flashing,then press K3,ten digit changes; K2 bit digital tube starts flashing, then press K3, single-digit change;then K2,; digital pipe does not ,then press the K3, shifting the decimalpoint,the decimalpointin abitindicates 0-999minutesin ten represents 0 to 99.9 seconds withou tadecimalpointrepresents 0-999 seconds;goodchoice,bringing the for time setting is completed.Short press ,enterfunction offine-tuning settings,triggerthedefaultdelayperiod is invalid, press , during the delay active(re-timing),clickon the , during the delay reset (timer turned off,the reset) press again to repeat the default settings for the first for time.
P1-2 operating modes:Asignal ,digital countdown begins,X seconds after,there lay open Y seconds,then close.Users can set the
for time X,Y;P1-1different for time settings similar to the blue lights that set the for time,blue light indicates setting off for time. Short press ,
enter function offine-tuning the set,the default is invalid during the delay,pressK1,during the delay active(re-timing),then the first repeat default settings.
P1-3 operating modes:Open X seconds,disconnect Yseconds, loop.Users can set the for ,Y;for time setting similar to P1-2.Short press ,enter function offine-tuning set,The default function is:set up electric circuit the first open, press the ,there lay first close.Press again to repeat the default functionality.
P1-4 operating modes:a to the open but do not start the timer,when the disappears,digital count down begins,X
for time after,the relayclose; During the delay,again to the ,digital count down canceled, stays energized, the disappears, count down; (equivalentto release the button to start timing, commonly usedin power-offdelay).Users canset the for time X; for time setting similar to P1-1.
Package includes:
1 x DC12V Delay Timer Control Module