DAE P153-400 Kit, UL kWh Smart Submeter, 1P3W(2 hot wire,1 neutral) 400A, 120/240v, 2 Split CTs, RS485
DAE P153-400 Kit, UL kWh Smart Submeter, 1P3W(2 hot wire,1 neutral) 400A, 120/240v, 2 Split CTs, RS485
Hero image 0 of DAE P153-400 Kit, UL kWh Smart Submeter, 1P3W(2 hot wire,1 neutral) 400A, 120/240v, 2 Split CTs, RS485, 0 of 6

DAE P153-400 Kit, UL kWh Smart Submeter, 1P3W(2 hot wire,1 neutral) 400A, 120/240v, 2 Split CTs, RS485

(No ratings yet)
DAE P153-400 Kit, UL kWh Smart Submeter, 1P3W(2 hot wire,1 neutral) 400A, 120/240v, 2 Split CTs, RS485DAE P153 400 Kit UL kWh Smart Submeter 1P3W 2 hot wire 1 neutral 400A 120 240v 2 Split CTs RS485DAE P252 200 with 1 CT inner dia 1 02 200A 480v UL RS485 kWh Smart Submeter 1P2W 2 hot wire no NeutralDAE P103 200 Kit UL kWh Smart Submeter Polaris 1000 1 phase 3 wire 2 hot wire 1 Neutral 200A 120 240v 2 Split Core CTsDAE P252 200 S Kit 200A 480v UL RS485 kwh Smart Submeter 3P3W 3 Hot Wire no Neutral 2 CTs inner dia 1 02DAE P102 200 S Kit 120V 200A 1P2W 1 hot wire 1 Neutral UL kWh Smart Submeter 1 CT dia 1 02DAE P152 200 S Kit 120V 200A 1P2W 1 hot wire 1 Neutral UL kWh Smart Submeter 1 CT dia 1 02 RS485DAE P256 600 S Kit 600A 277 480v UL kWh Smart Submeter 3P4W 3 hot wire 1 Neutral 3 CTs inner dia 1 38 RS485DAE P103 100 Kit UL kWh Smart Submeter Polaris 1000 1 or 2 phase 3 wire 2 hot wire 1 Neutral 100A 120 240v 2 Split Core CTsDAE P256 400 S Kit 400A 277 480v UL kWh Smart Submeter 3P4W 3 hot wire 1 Neutral 3 CTs inner dia 1 38 RS485DAE P253 200 KIT 208 240V 200A 3P3W 3 hot wire no Neutral UL kWh Submeter 2 Split CTs dia 0 94 RS485DAE P103 400 Kit UL Listed kWh Smart Submeter 1P3W 2 hot wire 1 neutral 400A 120 240V 2 Split CTs inner dia 1 38DAE P204 600 Kit 600A UL kWh Smart Submeter 3P4W 3 hot wire 1 neutral 120 208V 3 Split CTs inner dia 1 38 inDAE P206 600 S Kit 600A 277 480v UL kWh Smart Submeter Polaris 2000 3P4W 3 hot wire 1 Neutral 3 CTs inner dia 1 38DAE P252 400 S Kit 400A 480v UL RS485 kWh Smart Submeter 3P3W 3 hot wire no Neutral 2 CTs inner dia 1 02DAE P204 600 S Kit UL kWh Smart Submeter 3P4W 3 hot wire 1 Neutral 600A 120 208v 3 Solid Core CTs inner dia 1 38DAE P256 100 KIT UL kWh Smart Submeter 3Phase 100A 277 480v 3 CTs RS485DAE P103 400 S Kit UL Listed kWh Smart Submeter 1P3W 2 hot wire 1 neutral 400A 120 240V 2 CTs inner dia 1 38DAE P252 600 S KIT 400A 480v UL RS485 kWh Smart Submeter 3P3W 3 hot wire no Neutral 2 CTs inner dia 1 38DAE P153 200 Kit UL kWh Smart Submeter 1 phase 3 wire 2 hot wire 1 neutral 200A 120 240v 2 Split Core CTs RS485DAE P253 200 S Kit 208 240V 200A 3P3W 3 hot wire no Neutral RS485 UL kWh Smart Submeter 2 CTs dia 1 02DAE P253 400 S Kit 208 240V 400A 3P3W 3 hot wire no Neutral RS485 UL kWh Smart Submeter 2 CTs dia 1 38DAE P206 200 S Kit 200A 277 480v UL kWh Smart Submeter Polaris 2000 3P4W 3 hot wire 1 Neutral 3 CTs inner dia 1 02DAE P254 400 Kit 400A UL kWh Smart Submeter 3P4W 3 hot wire 1 neutral 120 208V 3 Split CTs inner dia 1 38 in RS485DAE P252 400 Kit 400A 480V UL RS485 kWh Smart Submeter 3P3W 3 hot wire no Neutral 2 Split CTs inner dia 1 38DAE P206 400 S Kit 400A 277 480v UL kWh Smart Submeter Polaris 2000 3P4W 3 hot wire 1 Neutral 3 CTs inner dia 1 38DAE P254 200 S Kit UL kWh Smart Submeter 3 phase 4 wire 3 hot wire 1 neutral 200A 120 208v 3 CTs RS485DAE P204 100 Kit UL kWh Smart Submeter 3P4W 3 hot wire 1 neutral 100A 120 208v 3 Split Core CTsDAE P203 200 S Kit 208 240V 200A 3P3W 3 hot wire no Neutral UL kWh Smart Submeter 2 CTs dia 1 02DAE P254 400 S Kit UL kWh Smart Submeter 3P4W 3 hot wire 1 Neutral 400A 120 208v 3 Solid Core CTs inner dia 1 38 RS485DAE P252 600 KIT 600A 480V UL RS485 kWh Smart Submeter 3P3W 3 hot wire no Neutral 2 Split CTs inner dia 1 38DAE P203 200 KIT 208 240V 200A 3P3W 3 hot wire no Neutral UL kWh Submeter 2 Split CTs dia 0 94DAE P204 200 S Kit UL kWh Smart Submeter 3P4W 3 hot wire 1 Neutral 200A 120 208v 3 Solid Core CTs inner diameter 1 02DAE P252 200 Kit 200A 480v UL RS485 kWh Smart Submeter 3P3W 3 hot wire no Neutral 2 Split CTs inner dia 0 94DAE P256 200 Kit 200A 277 480v UL RS485 kWh Smart Submeter 3P4W 3 hot wire 1 Neutral 3 CTs inner dia 0 94DAE P256 600 Kit 600A RS485 277 480v UL kWh Smart Submeter 3P4W 3 hot wire 1 neutral 3 Split CTs inner dia 1 38 inDAE P153 200 S Kit UL kWh Smart Submeter 1 phase 3 wire 2 hot wire 1 neutral 200A 120 240v 2 CTs RS485DAE P204 400 Kit 400A UL kWh Smart Submeter 3P4W 3 hot wire 1 neutral 120 208V 3 Split Core CTs inner dia 1 38 inchDAE P154 200 S Kit RS485 208 240V 200A 1P2W 2 hot wire UL kWh Smart Submeter 1 CT dia 1 02DAE P256 400 Kit 400A 277 480v UL kWh Smart Submeter 3P4W 3 hot wire 1 neutral 3 Split Cores CTs inner dia 1 38 inchDAE P104 200 S Kit 208 240V 200A 1P2W 2 hot wire UL kWh Smart Submeter 1 CT dia 1 02DAE P254 200 Kit UL kWh Smart Submeter 3 phase 4 wire 3 hot 1 neutral 200A 120 208v 3 Split Core CTs RS485DAE P254 600 Kit 600A RS485 UL kWh Smart Submeter 3P4W 3 hot wire 1 Neutral 120 208V 3 Split Core CTs inner dia 1 38 inchDAE P153 400 S Kit UL kWh Smart Submeter 1P3W 2 hot wire 1 neutral 400A 120 240V 2 CTs RS485DAE P256 200 S Kit 200A 277 480v UL RS485 kWh Smart Submeter 3P4W 3 hot wire 1 Neutral 3 CTs inner dia 1 02
Amps:400 Amps
Shape:W/ RS485, Split CTs
Size:120/240V, 2 hot, 1 neutral

Key item features

  • UL/CUL Listed, California CTEP Approved. Certified by independent test lab to exceed ANSI C12.1 national accuracy standards. Revenue-grade 0.5% accuracy. Comes with a lower cover which has two 3/4" knockouts to connect the conduits. One in-inline fuse with holder is attached for you to connect hot wire A to VA of the meter. The meter is powered by VA and VN. VB and VC just take the reference of voltage from hot wire B, C. They do not need in-inline fuse.
  • DAE Cloud Metering (2nd picture) available with DAE CC2030 Gateway. CC2030 will collect energy data from DAE electrical meters and send them to Cloud Server through Ethernet. With PC, cell phone or tablet, landlords or property managers can get access to real time data, monthly kWh and billing reports to their tenants. TOU (Time of Use) billing reports are also available. No IT guy required. Just connect wires as per a simple picture (see video) & ready to go.
  • For existing building, hard to draw cable between electric meter (close to electric panel) and CC2030 (close to your router), please choose 1 CC2030 KIT + 2 WSC500A RF Converters to connect electric meter and CC2030 wirelessly (3rd picture). Indoor use only, DAE B1725 watertight enclosure is available for outdoor use.
  • Factory Calibration Certificates available. DAE Controls LLC is an Minority Business. Please feel free to get the NMSDC Minority Supplier Certificate from DAE Controls Website. Following CTs are available with the meter. Split Core CTs DAE CT-5000SB (5000A), CT-3000SB (3000A), CT-2000SB (2000A), CT-1500SB (1500A), CT-1000SB (1000A), CT-600S (600A), CT-400S (400A), CT-200SB (200A), CT-100S (100A) and Solid Core CT-600D9 (600A), CT-400D6 (400A), CT-200D3 (200A).
  • For monitoring up to 8 electric panels remotely with cell phone, PC and generate billing reports, you will just need 1 SMB350-UL-8-B KIT + 1 CC2030 KIT.
Current price is $427.85
Price when purchased online
  • Free shipping
  • Free 30-day returns

How do you want your item?

How do you want your item?
Columbus, 43215
Arrives by Fri, Apr 10
|
Sold and shipped by DAE Controls LLC
5 stars out of 5, based on 3 seller reviews(5.0)
Report an issue with this seller
Free 30-day returns

About this item

Product details

Specifications

Warranty

Customer ratings & reviews

0 ratings|0 reviews
This item does not have any reviews yet