2.2KW VFD Solar Inverter 3HP DC 200-400V Input 1-Phases 0-220 Output Frequency Converter Water Pump Driver MTTP Speed Control
Key item features
- Type selection instructions:
- 1. Please read the product instructions carefully, choose the type according to the function and power you need, and avoid the dama caused by wrong wiring.
- 2. This frequency converter can not drive other load types except inductive load such as motor . Please pay special attention to it when purchasing.
- 3. The total input power of solar DC should be greater than that of photovoltaic converter, and the power of photovoltaic converter should be greater than or equal to the total load power driven by it.
- 4. The ran of DC input volta can refer to the best input value in the selection table to ensure the most efficient operation of frequency converter and motor. Changing the DC input volta can be achieved by changing the series and parallel connection of solar panels.
- Function
- Built-in MPPT controller:
- MPPT: full name "Maximum Power Point Tracking". It can detect the neration volta of solar panels in real time, and track the maximum volta and current value (VI), so that the system can output the driving load with the maximum power and apply it to solar photovoltaic system to coordinate the work between solar panels and loads. It's the brain of photovoltaic systems.
- Supporting Wide Volta Input;
- A, 220 photovoltaic converter corresponding input volta below 200V will jump low-volta alarm shutdown, 400V above automatically suppress volta rise, avoid overlooking overvolta shutdown;
- B, 380V photovoltaic converter corresponding input volta below 400V will jump low-volta alarm shutdown, 700V above automatically suppress volta rise, avoid overlooking overvolta shutdown.
- Support unattended automatic start and stop.
- In the morning, when the illumination intensity rises to a certain extent, the input volta reaches about 400 V (220 V photovoltaic converter reaches about 200 V), and the photovoltaic converter automatically starts driving load operation without manual operation.
- In the evening, when the illumination intensity decreases to a certain extent, the input volta drops to about 400 V (220 V photovoltaic converter reaches about 200 V), and the photovoltaic converter automatically stops driving the load without manual operation.
- Our products can provide motor protection function.
- Such as Short-circuit, phase-absence, over-current, over-volta, under-volta, over-heat, over-load protection, etc.
- Input and output characteristics
- 220 type (D1T)
- Input volta ran: DC 200V-400V(best for 300V-320V) or single phase 220±15% 50/60Hz
- Output volta ran: AC Three phase 0-220 0-400Hz
- 380V type (D3T)
- Input volta ran: DC 400V-700V(best for 530V-550V) or three phase 380V±15% 50/60Hz
- Output volta ran: AC Three phase 0-380V 0-400Hz
- Peripheral interface features
- Programmable digital input: 4 inputs
- Programmable analog input: AI1: 0 ~ 10V input, AI2: 0 ~ + 5V or panel potentiometer input
- Open collector output: 1 output
- Relay output: 1 output
- Analog output: 1 output, optional 4 ~ 20mA or 0 ~ 10V
Specs
- Surge wattage2.2 kW
- Volts220 V, 380 V
- BrandEugene Color
- FeaturesAutomatic
- Has written warrantyNo
- Vehicle fitment typeSpecific
- Free shipping
Free 30-day returns
(Only one option can be selected at a time)
How do you want your item?
About this item
Product details
1. Please read the product instructions carefully, choose the type according to the function and power you need, and avoid the dama caused by wrong wiring.
2. This frequency converter can not drive other load types except inductive load such as motor . Please pay special attention to it when purchasing.
3. The total input power of solar DC should be greater than that of photovoltaic converter, and the power of photovoltaic converter should be greater than or equal to the total load power driven by it.
4. The ran of DC input volta can refer to the best input value in the selection table to ensure the most efficient operation of frequency converter and motor.
5.Changing the DC input volta can be achieved by changing the series and parallel connection of solar panels.
- Type selection instructions:
- 1. Please read the product instructions carefully, choose the type according to the function and power you need, and avoid the dama caused by wrong wiring.
- 2. This frequency converter can not drive other load types except inductive load such as motor . Please pay special attention to it when purchasing.
- 3. The total input power of solar DC should be greater than that of photovoltaic converter, and the power of photovoltaic converter should be greater than or equal to the total load power driven by it.
- 4. The ran of DC input volta can refer to the best input value in the selection table to ensure the most efficient operation of frequency converter and motor. Changing the DC input volta can be achieved by changing the series and parallel connection of solar panels.
- Function
- Built-in MPPT controller:
- MPPT: full name "Maximum Power Point Tracking". It can detect the neration volta of solar panels in real time, and track the maximum volta and current value (VI), so that the system can output the driving load with the maximum power and apply it to solar photovoltaic system to coordinate the work between solar panels and loads. It's the brain of photovoltaic systems.
- Supporting Wide Volta Input;
- A, 220 photovoltaic converter corresponding input volta below 200V will jump low-volta alarm shutdown, 400V above automatically suppress volta rise, avoid overlooking overvolta shutdown;
- B, 380V photovoltaic converter corresponding input volta below 400V will jump low-volta alarm shutdown, 700V above automatically suppress volta rise, avoid overlooking overvolta shutdown.
- Support unattended automatic start and stop.
- In the morning, when the illumination intensity rises to a certain extent, the input volta reaches about 400 V (220 V photovoltaic converter reaches about 200 V), and the photovoltaic converter automatically starts driving load operation without manual operation.
- In the evening, when the illumination intensity decreases to a certain extent, the input volta drops to about 400 V (220 V photovoltaic converter reaches about 200 V), and the photovoltaic converter automatically stops driving the load without manual operation.
- Our products can provide motor protection function.
- Such as Short-circuit, phase-absence, over-current, over-volta, under-volta, over-heat, over-load protection, etc.
- Input and output characteristics
- 220 type (D1T)
- Input volta ran: DC 200V-400V(best for 300V-320V) or single phase 220±15% 50/60Hz
- Output volta ran: AC Three phase 0-220 0-400Hz
- 380V type (D3T)
- Input volta ran: DC 400V-700V(best for 530V-550V) or three phase 380V±15% 50/60Hz
- Output volta ran: AC Three phase 0-380V 0-400Hz
- Peripheral interface features
- Programmable digital input: 4 inputs
- Programmable analog input: AI1: 0 ~ 10V input, AI2: 0 ~ + 5V or panel potentiometer input
- Open collector output: 1 output
- Relay output: 1 output
- Analog output: 1 output, optional 4 ~ 20mA or 0 ~ 10V