| AC input voltage range | 90~264VAC 127~370VDC |
| AC inrush current | Cold start :30A/115VAC 60A/230VAC |
| Overload protection | 110~140% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed |
| Over voltage protection | 12V:13.2~15.6V, 15V:16.5~19.5V, 24V:26.4~31.2V, 36V:39.6~46.8V, 48V:52.8~62.4V Protection type :Shut down O/P voltage, re-power on to recover |
| Setup, rise, hold up time | 2000ms, 80ms/230VAC/115VAC at full load; 10ms/115VAC, 230VAC |
| Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.25KVAC |
| Working temperature | -30~+70℃ (Refer to Derating Curve) |
| Safety standards | UL60950-1, TUV EN60950-1, EN60335-1, CCC GB4943, EAC TP TC 004, BSMI CNS14336-1 approved, Design refer to EN61558-1,-2-16 |
| EMC standards | Compliance to EN55032, GB9254, Class B, EN55014, EN61000-3-2, -3, EAC TP TC 020, BSMI CNS13438; Compliance to EN61000-4-2, 3, 4, 5, 6, 8, 11 ;EN61000-6-2 (EN50082-2), heavy industry level, criterial A, EAC TP TC 020 |
| Dimension (LxWxH) | 220×62×31mm |
| Packing | 0.68Kg;16pcs/11.88Kg |