| AC input voltage range | 90~305VAC ; 127~431VDC |
| AC inrush current (max.) | Cold start, 50A at 230VAC |
| Overload protection | 108%~120% hiccup mode, auto-recovery |
| Over voltage protection | 113%~142% rated output voltage |
| Over temp. protection | Shut down output voltage, re-power on to recover |
| Setup, rise, hold up time | 500ms, 80ms, 16ms at full load and 230VAC |
| Setup, rise, hold up time | 1000ms, 80ms, 16ms at full load and 230VAC |
| Withstand voltage | I/P-O/P: 3.75kVAC |
| Working temperature | -40~+70ÂșC (refer to output derating curve) |
| Safety standards | UL8750, ENEC EN61347-1, EN61347-2-13, EN62384 approved (PWM-40/60/120 pending); Design refer to EN60335-1 |
| EMC standards | EN55015, EN61000-3-2 class C, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 (PWM-40/60/120 pending) |
| Connection Input | UL rated, SJTW 18AWGx3C (30cm) |
| Connection Output | UL2464 18AWG x2C (30cm)+ 22AWG x2C (30cm) |
| Dimension (LxWxH) (mm) | 150x 53x 35 |