| AC input voltage range | 90~305VAC ; 127~431VDC |
| AC inrush current (max.) | Cold start, 35A at 230VAC |
| DC adjustment range | 90%~110% rated output voltage |
| Current adjustment range | 75%~103% |
| Over current protection | 100%~110% constant current limiting, auto-recovery |
| Over voltage protection | 110%~155% rated output voltage |
| Setup time | 2000ms at full load and 230VAC |
| Withstand voltage | I/P-O/P: 3.75kVAC |
| Working temperature | -30~+50OC (refer to output derating curve) |
| Safety standards | UL1310, TUV EN61347-1, EN61347-2-13, PSE J61347-1, J61347-2-13 approved; TUV EN60950-1 approved for PLC-100 only |
| EMC standards | EN55015, EN55022 class B (PLC-45/60/100), EN61000-3-2 class C, EN61000-3-3, EN61000-4-2, 3, 4, 5, 6, 8, 11, EN61547 |
| Connection (Input / Output) | 2+2P screw terminal block |
| Dimension (LxWxH)(mm) | 160x 46x 30 |
| Packing | 0.2kg ; 70pcs / 15kg |