KSP-F01A 12V Peristaltic Metering Pump/Aquarium Dosing Pump
Basic Parameters
Motor: DC Motor
Voltage: 12V
Power: 12W
Current: 1A
Flow rate: 27-40ml/min
Roller: 3 rotors
Tube: PharMed BPT tube
Volume: 1-9999 ml
Precision: Less than ±2%
Times add: 96times /day; 1time/4 days
Temperature: 0~70
Humidity: 10%-90% Non-solidification
Weight: 660g
Size: 200*170*110mm
Reversible: Yes
Customize: Yes
Various Applications
1. Quantitatively add aquarium additives, such as Ca, Mg and kH supplements.
2.Timing, quantitative dispensing a liquid in Laboratory.
3.Timing, quantitative dispensing a liquid Via an external signal control
4.Other Timing, quantitative dispensing a liquid occasion
Packing List
1 × Cable for extend channel
1 × Power supply
3 meters PVC connector tube(3.0*5.0 mm)
1 × Cylinder(10ml)
KSP-F01A Main unit
Product certification
1 × Pump head with BPT tube
2 pcs × Connectors
More Details
1. Button
2. LCD display
3. LCD protective screen
4. Pump head component
5. BPT Tubing
6. Speed control knob
7. CE sign
8. DC IN
9. DC OUT
Button Introduction
Manual key: Click to run or stop pump manually
Calibrate key: Click to start flow calibration
Set key: Click to switch the parameters to be set
OK key: Click to confirm the set parameters
Auto key: Click to start or stop automatic mode
Display Introduction
Run: the field of run page
Delay: the field of delay page
From: the field of start time of period page
To: the field of end time of period page
Clock: the field of clock page
Operation Mode
Manual
press the "Manual" key to start running; press the "Manual" key to stop when running
Note: Only this mode support speed adjust by knob.
Single quantitative add
After reaching the setting amount the pump will stop.
Note: After setting, press "Auto" to run.
Cycle quantitative add
Set amount and time, then the pump will run cyclically.
Note: Press "Auto" to start, and press "Auto" again to stop .
Single quantitative add during a certain time
In setting time, the pump will run
Note: Press "auto" add to start, and press "auto" again to stop.
Cycle quantitative add during a certain time
Set amount and time, then the pump will run cyclically during this time.
The pump will not work without the time you set.
Note: Press "auto" to start, and press "auto" again to stop.
KSP-F01A Dosing Pump - Maintenance
Pump head components and motor is the consumables, need regularly replace. Components of pump head: replace after running 1000 hours.
Motor: After running 800 hours, it need to replace.
If use in high load, high humidity, high dust environment, replace the motor pump due to the working situations.
Warmth Warning
Power Adapter
Please do not make this product fell into the water, in order to avoid electronic parts damaged or short circuit burned.
Cable for extend channel