Hero image 0 of TRIPP LITE PDUMH15ATNET PDU SWITCHED 1.4KW 120V 15A 1U 8 5-15R 2 5-15P ATS RM 12FT CORDS, 0 of 3
TRIPP LITE PDUMH15ATNET PDU SWITCHED 1.4KW 120V 15A 1U 8 5-15R 2 5-15P ATS RM 12FT CORDS
(No ratings yet)
Key item features
Key Features and Benefits:
- 120V 15A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 12A continuous)
- Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord
- Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
- Digital display continuously reports total output power consumption in amps
- 8 switched NEMA 5-15R outlets
- 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth
- Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources
- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
- Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds
- LX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
- DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
- Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA)
- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
- Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized
- Front panel LEDs confirm power availability on both input lines
- Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
What's Included:
- ATS / Switched PDU with attached 5-15P input power cord
- Detachable C13 to NEMA 5-15P 12 ft / 3.6m secondary input cord
- Installable 1U mounting brackets
- User manuals with warranty information
Specs
- BrandTripp Lite
- Watts1400 Watts
- VoltsAC 120 V
- ColorWhite
- Dimensions14.50 x 17.50 x 1.70 Inches
- Weight1.7 in
Price when purchased online
Not Available
How do you want your item?
Not available
About this item
Product details
PDUMH15ATNET PDU SWITCHED 1.4KW 120V 15A 1U 8 5-15R 2 5-15P ATS RM 12FT CORDS
Key Features and Benefits:
- 120V 15A Automatic Transfer Switch (ATS) / Switched PDU (Agency de-rated to 12A continuous)
- Provides a redundant A/B power option for non-redundant networking equipment with a single input power cord
- Switched PDU features enable programmable or real-time power control of individual outlets via built-in network interface
- Digital display continuously reports total output power consumption in amps
- 8 switched NEMA 5-15R outlets
- 1U horizontal rackmount form factor; 14.5 in. / 36.8 cm depth
- Set of two 12 ft. / 3.6m NEMA 5-15P input cables support connection to separate PRIMARY and SECONDARY power sources
- ATS circuits normally maintain output sourced from the primary input cable; As primary input power fails or becomes unstable, the ATS will switch to maintain output sourced from the secondary input cable until power on the primary input is restored and stable
- ATS configurations enable fault-tolerant, hot-swappable UPS protection when used with a single UPS and fully redundant UPS protection when each cord is connected to a separate UPS system (in a two-UPS environment, the primary input cable must be supported by an online UPS with zero transfer time similar to Tripp Lite SmartOnline series)
- Advanced ATS configurations utilizing separate mains circuits, backup generators and even separate out of phase utility power grid feeds are fully supported
- On-board ATS processor constantly evaluates power quality on both inputs to prevent transfer to the secondary source when unavailable or of lower quality than the primary source
- Super-fast switchover between primary and secondary power sources occurs in 2-7 milliseconds
- LX Platform interface allows full remote access for power monitoring with email notifications via secure web browser, SNMP, telnet or SSH
- DHCP/Manual configuration support; Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP, NTP protocols
- Auto Probe feature (Firmware 15.5.2 and greater) checks the connectivity status of any networked device and automatically takes one or more user-configured actions if the device fails to respond; actions include outlet reboot, set SNMP traps, SNMP OID sets, and even script execution when used in conjunction with the Tripp Lite PowerAlert Network Shutdown Agent (PANSA)
- Optional EnviroSense2 modules (sold separately) provide a variety of environmental monitoring capabilities
- Outlets are factory programmed for sequential turn-on at 250 millisecond intervals as the PDU is first energized
- Front panel LEDs confirm power availability on both input lines
- Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases
What's Included:
- ATS / Switched PDU with attached 5-15P input power cord
- Detachable C13 to NEMA 5-15P 12 ft / 3.6m secondary input cord
- Installable 1U mounting brackets
- User manuals with warranty information
info:
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here, and we have not verified it. Â
Specifications
Brand
Tripp Lite
Watts
1400 Watts
Volts
AC 120 V
Color
White
Check out these related products
PDU SWITCHED 1.9KW 8 5-15/20R $549.95
$54995current price $549.95PDU SWITCHED 1.9KW 8 5-15/20R
PDU SWITCHED 120V 1.4KW 15A $515.00 $515.00/oz
$51500current price $515.00$515.00/ozPDU SWITCHED 120V 1.4KW 15A
15 out of 5 Stars. 1 reviewsCyberPower 3-Phase Switched Metered-By-Outlet PDU with NEMA L15-30P 30A Cord $2,033.55
$2,03355current price $2,033.55CyberPower 3-Phase Switched Metered-By-Outlet PDU with NEMA L15-30P 30A Cord
Tripp Lite Metered PDU with ATS, 15A, 8 Outlets (5-15R), 120V, 2 5-15P, 100 - 127 V Input, 2 12 ft. Cords, 1U Rack-Mount Power, TAA (PDUMH15AT) $452.57
2 optionsAvailable in additional 2 options$45257current price $452.57Tripp Lite Metered PDU with ATS, 15A, 8 Outlets (5-15R), 120V, 2 5-15P, 100 - 127 V Input, 2 12 ft. Cords, 1U Rack-Mount Power, TAA (PDUMH15AT)
24.5 out of 5 Stars. 2 reviewsTripp Lite Switched PDU with ATS, 1.4kW Single-Phase 120V (8 5-15R), 2 5-15P, 100 - 127V Input, 2 12 ft. Cords, 1U Rack-Mount, TAA (PDUMH15ATNET) $643.39
$64339current price $643.39Tripp Lite Switched PDU with ATS, 1.4kW Single-Phase 120V (8 5-15R), 2 5-15P, 100 - 127V Input, 2 12 ft. Cords, 1U Rack-Mount, TAA (PDUMH15ATNET)
Tripp Lite TLP606USBB Protect It! 6-Outlet Surge Protector with 2 USB Ports, 6ft Cord $34.04 Was $47.24
2 optionsAvailable in additional 2 options$3404current price $34.04, Was $47.24$47.24Tripp Lite TLP606USBB Protect It! 6-Outlet Surge Protector with 2 USB Ports, 6ft Cord
134.8 out of 5 Stars. 13 reviewsTripp Lite 1900W Switched PDU, Single Phase ATS with LX Platform, 120V Outlets (16 5-15/20R), 2 L5-20P / 5-20P 12ft 120V Inputs, 1U Rack Mount, TAA (PDUMH20ATNET) $755.78 $1.38/ea
$75578current price $755.78$1.38/eaTripp Lite 1900W Switched PDU, Single Phase ATS with LX Platform, 120V Outlets (16 5-15/20R), 2 L5-20P / 5-20P 12ft 120V Inputs, 1U Rack Mount, TAA (PDUMH20ATNET)
43.8 out of 5 Stars. 4 reviewsAPC Rack PDU, Switched, 1U, 20A, 120V, (8) 5-20 (AP7901B) $643.50 Was $983.29
$64350current price $643.50, Was $983.29$983.29APC Rack PDU, Switched, 1U, 20A, 120V, (8) 5-20 (AP7901B)
35 out of 5 Stars. 3 reviewsTripp Lite 8 Outlet 1.44kW 120V Single-Phase ATS/Monitored PDU PDUMNH15AT1 $663.43
$66343current price $663.43Tripp Lite 8 Outlet 1.44kW 120V Single-Phase ATS/Monitored PDU PDUMNH15AT1
Customer ratings & reviews
0 ratings|0 reviews
This item does not have any reviews yet