| AC input voltage range | 90~264VAC; 127~370VDC |
| AC inrush current (max.) | Cold start, 35A at 230VAC |
| DC adjustment range | 12V: 12~14V, 24V: 24~28V, 48V: 48~55V |
| Current adjustment range | 10%~100% rated output current adjustable by 1~10Vdc, PWM signal or resistance |
| Overload protection | 105%~130% Constant current limiting, auto-recovery |
| Over voltage protection | 14V: 14~17V, 24V: 29~33V, 48V: 56~65V |
| Over temperature protection | Shut down o/p voltage, re-power on to recover |
| Withstand voltage | I/P-O/P: 3kVAC, I/P-FG: 2kVAC, O/P-FG: 0.5kVAC |
| Working temperature | -20~+70!aC (refer to output derating curve |
| Safety standards | UL60950-1, TUV EN60950-1 approved |
| EMC standards | EN55022 class B, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11, EN61000-6-2(EN50082-2), EN61204-3 |
| Connection (screw DIN terminal) | I/P: 3 poles, O/P: 4 poles |
| Dimension (LxWxH) (mm) | 40x 125.2x 113.5 |